Q: What impact does improper use of current density have on the coating?

16/04/2024 11:10:45 1    answers in: Other
Social Share:
A

① In the electrolyte without additives, as the cathode current density increases, the coating will crystallize and become rough;

② When the cathode is not moving or stirring, excessive cathode current density will make the coating dark and rough;

③ Depending on the content of zinc ions, too high a cathode current density will cause local burning of the parts.

Solution: Depending on the zinc ion content in the electrolyte, we can control the cathode current density within the range of 1~2.5A/dm².